Sunday 2 December 2018

Engine Controls - Progman(R) V21.0 Errors


Engine Controls - Progman(R) V21.0 Errors



SI M 09 01 06



Programming/Coding Explanation



March 2006



Technical Service



SUBJECT



Release Notes Progman V21.0



MODEL



All



SITUATION



2002-2006 Mini Cooper (R50) L4-1.6L (W10) Page 223



Progman V21.0 has been released. Certain errors may occur during installation or usage.



CAUSE



Software error



COMPLAINT



The following issues are currently known:



1. "Back" button is missing after the "Change" button in the menu bar has been selected.



2. An incorrect CIP version may be displayed on the "Online update" screen after a JETStream update.



3. Once the installation has been completed, the subsequent reboot of the SSS R1 may not be carried out correctly.



4. It may no longer be possible to use the GT1 after selecting "Update software".



5. In some cases, no status display (white screen) appears for a few minutes if a measures plan is cancelled.



6. After successful programming, the final report shows incorrect number of remaining programming attempts for the affected control unit.



7. "The SSS installation data could not be determined. (Code=45124, Msg=45042)" is displayed.



8. No FASTA data has been transferred for a long period of time.



9. Individual coding/programming process stages (e.g. Clear fault memory, full coding) may be displayed in the final report with error code



14031.



10. The session does not start from the GT1 terminal. An error message ("Bad request") appears instead of the "Continue" button.



11. Errors are shown in the final report. Information about the affected control unit is missing.



12. Coding of the MRS control unit (MRS5) may fail after replacement.



13. The DVD eject lock button is not displayed in Progman retrofit menu.



PROCEDURE



1. Button is hidden behind the "Minimize" button, no workaround.



2. Ignore the incorrect CIP version displayed.



3. In the event of an error, reboot by pushing and holding in the SSS power button.



4. Proceed as follows: 1. Disconnect the GT1 cable and wait until an error message notifies you of the loss of connection. 2. Reconnect the cable.



3. Update the SSS list. 4. Select the SSS again and end the session in the usual way.



5. Wait until the next screen appears. This may take a few minutes.



6. Ignore the incorrect display. Only when error 10022 (CIP) is displayed during DME programming, the control unit may no longer be



programmable.



7. Select "Online service," confirm setting by pressing the "Continue" button.



8. Check all FASTA and online service settings. If everything is correct reinstall Progman. However, the existing FASTA data will be lost.



9. The process for which an error is displayed must be repeated in the event of this error.



10. The session name entered on the terminal must not contain any spaces.



11. The control unit must be determined based on the actions carried out.



12. A pre-coded control unit must be ordered.



13. Request central coding key (ZCS) that includes the missing retrofit through PuMA.



2002-2006 Mini Cooper (R50) L4-1.6L (W10) Page 224